Tarek Q. Qasim, Tawfeq Al-Etaiwi, Mohammed Al-khasheb
Department of Industrial Engineering
Jordan University of Science and Technology, P. O. Box 3030
Irbid 22110, JORDAN
The developments of prompt gamma neutron activation analysis (PGNAA) and its functionality as on-line/real-time chemical analyzer attracted several industries to utilize this technology which provides accurate tracking and chemical mapping simultaneously. The cement industries are no exception. In this study, the installation of PGNAA system in Jordan, provided by Thermo Fisher Scientific Company at Lafarge Plant Cement Factory is examined. In collaboration with Lafarge, data were collected and analyzed. Comparison among manual testing methods utilized before and after installing the cross belt analyzer (CBA) had been made to improve the quality of final products rang and cost savings. The study has demonstrated that kiln feed uniformity index (KFUI) achieved Lafarge standard, and cost reduction of clay and pozzolana after installing CBA were achieved. The results of this study are important since several industries with similar products in Jordan could benefit from the outcome and recommendations made based on this case study at Lafarge in Jordan.
File Attachments: IEOM186.pdf
|